Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Infect Control ; 52(6): 635-643, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38408542

RESUMO

BACKGROUND: Outbreaks linked to inadequate endoscope drying have infected numerous patients, and current standards and guidelines recommend at least 10 minutes of forced air for drying channels. This study evaluated a new forced-air drying system (FADS) for endoscopes. METHODS: Drying was assessed using droplet detection cards; visual inspection of air/water connectors, suction connectors, and distal ends; and borescope examinations of endoscope interiors. Assessments were performed after automated endoscope reprocessor (AER) alcohol flush and air purge cycles and after 10-minute FADS cycles. RESULTS: Researchers evaluated drying during encounters with 22 gastroscopes and 20 colonoscopes. After default AER alcohol and air purge cycles, 100% (42/42) of endoscopes were still wet. Substantial fluid emerged from distal ends during the first 15 seconds of the FADS cycle, and droplets also emerged from air/water and suction connectors. Following FADS cycle completion, 100% (42/42) were dry, with no retained fluid detected by any of the assessment methods. CONCLUSIONS: Multiple endoscope ports and channels remained wet after AER cycles intended to aid in drying but were dry after the FADS cycle. This study reinforced the need to evaluate the effectiveness of current drying practices and illustrated the use of practical tools in a real-world setting.


Assuntos
Endoscópios , Humanos , Endoscópios/microbiologia , Dessecação/métodos , Desinfecção/métodos , Desinfecção/normas , Contaminação de Equipamentos/prevenção & controle
2.
Biomed Instrum Technol ; 58(1): 25-33, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38377297

RESUMO

Objective: Borescope examinations of endoscope channels are commonly described in literature, but no studies on surgical instrument lumen inspection have been published recently. Inadequately processed surgical instruments have been implicated in patient infections. This study assessed the utility of borescopes for inspecting surgical instruments. Methods: The study team inspected and photographed sterilized, patient-ready arthroscopic shaver handpieces and suction tips using a tablet camera and borescopes to characterize internal anatomy, defects found in lumens, and the impact of recleaning on debris or residues. Results: Ten suctions and eight shavers were inspected. All suctions had internal ridges and suction holes that were perpendicular to the lumen. All shavers had visible ridges, elbows, and lever mechanisms inside lumens. Of the 18 instruments, 16 (88%) had internal features that appeared rough or jagged and 17 (94%) had visible debris or discoloration in the lumens. Recleaning efforts generally were effective for suctions, but multiple rounds of recleaning with enhanced steps were less effective for shavers, which were replaced. Researchers documented retained soil and brush bristles in several new shavers despite following manufacturer instructions for cleaning and found visible damage and discoloration within five uses. Discussion: This study demonstrated the value of borescope examinations for surgical instrument lumens. Visual inspections identified anatomical features that could influence cleaning effectiveness and detected residual soil, discoloration, and debris in most instruments. The findings suggested that manufacturer cleaning instructions were insufficient and additional cleaning was not always effective. In response, the site's multidisciplinary team strengthened risk assessment protocols and enhanced their cleaning practices.


Assuntos
Desinfecção , Endoscópios , Humanos , Projetos Piloto , Instrumentos Cirúrgicos , Solo , Contaminação de Equipamentos/prevenção & controle
3.
Am J Infect Control ; 51(6): 624-632, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36907359

RESUMO

BACKGROUND: Health care is shifting toward minimally invasive procedures requiring increasingly complex instruments and sophisticated processing technologies. Effective training methods are needed to ensure sterile processing professionals acquire and retain essential skills. This study aimed to develop and evaluate a new training model that supports mastery and retention of complex key skills. METHODS: The model was pilot-tested with training focused on visual inspection of endoscopes. Pre- and post-training tests were administered to enhance learning during a face-to-face workshop that interspersed lectures and hands-on practice, followed by structured homework, and an online booster session. Surveys assessed satisfaction and confidence levels. RESULTS: Mean test scores for nine certified sterile processing employees increased significantly following the workshop (41% vs 84%, P < .001). After the workshop, all trainees identified actionable visible defects on patient-ready endoscopes in their facilities. Test scores remained high after 2 months (90%), and trainees reported higher technical confidence and satisfaction levels after training. CONCLUSIONS: This study demonstrated effectiveness and clinical relevance of a new, evidence-based model for training sterile processing professionals that incorporated pretesting, lectures, hands-on practice, a training booster, and post-testing to enhance learning. This model may be applicable to other complex skills necessary for infection prevention and patient safety.


Assuntos
Competência Clínica , Relevância Clínica , Humanos , Projetos Piloto , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA